The
Ax Control Panel Series
Our Ax range of user-friendly analogue addressable fire control panels were
designed using years of experience and in-depth technical expertise, to protect
your
buildings and your people.
The
range of fire detection and control equipment is based around
multi-circuit analogue addressable control panels complete
with SLC loops with 126 address's per circuit (Up to 1000
via sub
addressing, per panel), on board 2 Amp Notification Appliance
Circuits and a 5 Amp supply as standard expandable to 10Amps.
The full range, from One to Four loops, have been designed
to UL-864 and meet the NFPA Standard (Fire Alarm Code), for
use with Advanced Ax devices.
Annunciators,
Additional Peripherals and Software
We also offer an extensive range of remote annuciators, additional peripherals,
including input /output modules, printers and a variety of graphical indication
units,together with easy to use software for programming, diagnostics and control,
via
our user friendly Windows™ based PC-NET control and
communication packages.
The
Ax Device Series
Ax series intelligent analog fire devices offer a wide range of capabilities
to suit virtually any commercial or industrial application. Working in conjunction
with the Advanced Ax Series fire control panels,
premium protection is provided. Ax detectors readily adapt to changing environments
and protect against unwanted false alarms
 |
Features
at a Glance
- Standalone
or Networked
- 2
or 4 SLC per panel
- Up
to 1000 points/addresses per panel
- Large
Graphical LCD Display
|
|
Each detector
in the Advanced Ax range has dual LED’s providing 360° visibility
in an alarm condition and have the option to configure ‘individual’ or ‘all’ detector
blinking scheme. The detector series operate in one of five
response modes, which can be selected from the control panel.
The response characteristics of the detectors have been carefully
set so that the detectors will comply with the requirements
of the relevant part of UL268/521 in all response modes. Mode
selection depends on application, check data sheet for further
information.
Ax intelligent
I/O interfaces are easy to install, well protected and modular
in design. Systems can be engineered simply and effectively
without the need for custom designed equipment.
| Detector
Range |
 |
Optical
Smoke Detector
The Ax optical smoke detector is suitable for slow burning or smoldering
fires and should be positioned where these are most likely to occur. They
can be set to a sensitivity mode via the Ax range of control and indication
equipment which best suits the application
|
 |
Heat
Detector
The Ax heat detector, distinguishable by the low airflow resistant case,
uses a single thermistor to sense the air temperature around the detector.
This type of detector is particularly useful where the environment is dirty
or smoky under normal conditions. |
 |
Multisensor
Detector
The Ax multisensor detector comprises optical smoke and thermistor temperature
sensors whose seperate analogue values are intelligently combined. As a
result, the multisensor is useful over a wide range of applications and
is highly
immune to false alarms. |
 |
Ionisation
Smoke Detector
The Ax Ionisation detector is suitable for fast burning, flaming fires
and should be positioned where these are most likely to occur. They can
be set to a sensitivity mode via the Ax range of control of control and
indication equipment which best suits the application.
|
 |
Ax
Advanced Beam Detector
This SLC loop driven device comprises a transmitter, a receiver, an interface
and optionally, one or more reflectors. The beam detector is designed to
protect large and open spaces such as atriums, museums, warehouses and
factories. The transmitter and receiver are designed to be fitted on opposite
walls approximately 1ft to 2ft below the ceiling and they can protect areas
up to 300ft long and 45ft wide, a total of 13,500ft². |


|
Ax
Mounting Base Range
The
Ax Address card and Mounting base provides a unique, patented
addressing method whereby the address is set by simply
removing the ‘plastic tabs’ on the card according
to a chart supplied with the base. The coded card is then
inserted into the side of the base where it locks into
position.
The Ax-Address card simplifies and speeds up the installation and commissioning
process providing accurate addressing of the system making it easier
to swap over devices and prevent double address issues period.
|
 |
Pull
Station
The Ax Pull Station range is a family or versatile, analog addressable,
high quality, metal Pull Station for Fire Alarm (Red) and other input
signaling requirements. They can be addressed at the commissioning stage
by means of a seven-segment DIP switch. When operated, the Pull Station
incorporates a maximum of 3 second response time.
For
mounting options and technical specification refer
to document 682-004
|
| Interface
Range |
 |
Ax
Mini Priority Switch Monitor Module
Designed to monitor the state of one or more single-pole contacts connected
over Class A or B wiring. Reports open and ground-circuit trouble on the
sub-circuit. The device incorporates an interrupt facility to give the
fastest response to the Ax Analog control panels. The product is designed
to fit into a single-gang electrical box. |
 |
Ax
Mini Switch Monitor Module
Designed to monitor the state of one or more single-pole contacts connected
over Class A or B wiring. Reports open and short-circuit faults on the
sub-circuit and the product is designed to fit into a single-gang electrical
box. |
 |
Ax
Switch Monitor/Dual Switch Monitor Module
Designed to monitor the state of one or more single-pole contacts connected
over Class A or B wiring. Reports open and short-circuit faults on the
circuit and is used to monitor equipment where a response is required.
The product is mounted on a plastic mounting plate for use with a 4” electrical
box. |
 |
Ax
Priority Switch Monitor Module
This product has the same functionality as the standard Ax Switch monitor
module, but incorporates a priority interrupt facility to give the fastest
response to devices such as manual pull station. The product is mounted
on a plastic mounting plate for use with a 4” electrical box. |
 |
Ax
NAC Control Unit
This unit is designed to monitor and control one circuit of alarm sounders
or voice speakers powered by an external DC supply. The module incorporates
a synchronization facility which allows the outputs of groups of modules
to be synchronized by commands from the Ax series control panels. The product
is mounted on a plastic mounting plate for use with a 4” electrical
box. Class A or B wired circuit. |
 |
Ax
Switch Monitor Input/Output Module
This unit provides a loop-powered relay, a monitored input and an unmonitored
opto-coupled input. It can report trouble,switch open and switch closed
levels. The product is mounted on a plastic fascia plate for use with a
4” electrical box. For mounting options and Technical Specification
refer to document |